 Description   

Since the serverselectiontimeout doesn't carry a default value, if the client URI points to an invalid/unavailable mongod instance, the commands such as insert may block indefinitely. The default value should be 30000 ms as per the spec.



 Comments   
Comment by Kristofer Brandow (Inactive) [ 23/Apr/18 ]

This is fixed here: https://github.com/mongodb/mongo-go-driver/blob/12b7dca2ce8fe45b44a5e19df50f2ea121b5f2d9/core/topology/topology.go#L221-L224.

Comment by Kristofer Brandow (Inactive) [ 27/Mar/18 ]

This will be fixed by GODRIVER-254.