[SERVER-3132] Oplog should compensate for clock skew Created: 23/May/11  Updated: 12/Jul/16  Resolved: 04/Aug/11

Status: Closed
Project: Core Server
Component/s: Replication
Affects Version/s: None
Fix Version/s: 1.9.2

Type: Bug Priority: Major - P3
Reporter: Kristina Chodorow (Inactive) Assignee: Mathias Stearn
Resolution: Done Votes: 1
Labels: None
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Issue Links:
Depends
depends on SERVER-703 optime doesn't handle clock skew Closed
Operating System: ALL
Participants:

 Description   

http://groups.google.com/group/mongodb-user/browse_thread/thread/f7ed0194e3e3cdad



 Comments   
Comment by auto [ 04/Aug/11 ]

Author:

{u'login': u'RedBeard0531', u'name': u'Mathias Stearn', u'email': u'mathias@10gen.com'}

Message: Handle clock skew in replsets to ensure OpTimes always increase SERVER-3132
Branch: master
https://github.com/mongodb/mongo/commit/50d396b3f4b516cb125fa33c20e018f9a485c909