Type:
Task
-
Resolution: Fixed
-
Priority:
Major - P3
-
Affects Version/s: None
-
Component/s: None
-
None
-
Storage Execution
-
Fully Compatible
-
Storage Execution 2026-05-11, Storage Execution 2026-05-25
-
None
-
None
-
None
-
None
-
None
-
None
-
None
On step up, when resuming a primary-driven index build, one thing we need to do is delete any entries from the sorter table that don't fall within the ranges provided in the persisted index build metadata. In other words, we need to delete any keys that fall before the first range and any keys that fall after the last range.