      See BF-43904. 

      The main underlying issue is that the state machine doesn't serialise transitions, and we're running into a case here where another transition is holding the token, so our attempt to tryIssueToken() at the end of connectAsStandbyForStartup is met with a already held token, so we return none and then we invariant.

      Consider a retryable state instead, or a backoff. 