After SERVER-125964 initial syncs now perform a wait for their sync source to have a checkpoint timestamp. If we end up restarting both secondaries during a rolling restart and have them enter initial sync they will never make progress because the primary cannot advance due to lacking a majority quorum.
We need to apply the same fix as SERVER-128503 for `jstests/sharding/replica_set_promotion_demotion.js`.
- is related to
-
SERVER-128503 Wait for initial sync to complete during rolling restarts
-