Type:
Bug
-
Resolution: Fixed
-
Priority:
Major - P3
-
Affects Version/s: 9.1.0-rc0, 9.0.0
-
Component/s: None
-
None
-
Catalog and Routing
-
Fully Compatible
-
ALL
-
CAR Team 2026-11-09
-
0
-
None
-
None
-
None
-
None
-
None
-
None
-
None
On master, the test still writes immediately after the failover helper returns.
The helper waits for replica-set readiness, but not for mongos to recognize the new primary. Mongos can therefore route the insert to the old primary, now a secondary, which correctly refuses the write.