The test verifies that replica set write blocking remains enabled after a primary re-election. Currently, the test created a three-node replica set without specifying member priorities. The DSC passthrough assigns priority 1 to the initial primary and priority 0 to standby nodes. Because priority-0 members cannot become primary, the planned stepdown failed: neither standby was an eligible replacement. The test therefore never reached its post-election write-blocking checks.
As part of this ticket, we have to explicitly configure all three members with priority 1 and await replication before stepping down. This makes replacement primaries electable and ensures they have applied the write-block state before the handoff. Once this is done, we have to add the test to no_passthrough_disagg_override_replsets.
- related to
-
SERVER-138700 Investigate noPassthrough sharding coverage for tests applying replication lag injection
-
- Closed
-