• Type: Bug
    • Resolution: Unresolved
    • Priority: Major - P3
    • None
    • Affects Version/s: 8.0.13, 7.0.48
    • Component/s: Replication
    • None
    • Replication - Oplog and Recovery
    • ALL
    • None
    • None
    • None
    • None
    • None
    • None
    • None

      Versions: 7.0 and 8.0 confirmed. 9.0 and master: probably.

      Problem

      ReplicationCoordinatorImpl::signalDrainComplete runs on the OplogApplier thread. It takes AutoGetRstlForStepUpStepDown(kStepUp), and under the RSTL in X it does slow work:

      • the term-bump doOptimizedReconfig, which persists the config and waits for a journal flush;
      • onTransitionToPrimary: the session scan for prepared transactions, the no-op write, _dropAllTempCollections over every database, and the sharding hooks.

      OplogApplier is a system client that the kill pass cannot interrupt. If a new term arrives during this window, the step-down from _stepDownFinish waits behind the step-up's X and fasserts.

      Related but different: a step-up can also time out on the RSTL in signalDrainComplete itself, when other holders block it. That is a step-up blocked by other holders, not a step-down blocked by a step-up.

      Evidence

      • 7.0.48: two lock dumps with OplogApplier-0 holding the RSTL in X. In one, the term-bump reconfig alone took 5 to 7 s, and the X was held for more than 60 s. FTDC on both nodes shows empty ticket queues during the step-down.
      • 8.0.13: two dumps with the same holder, one of them with a _dropAllTempCollections stack.

      On master, signalApplierDrainComplete still takes AutoGetRstlForStepUpStepDown unconditionally, next to the intent registry's ReplicationStateTransitionGuard, so 9.0 and master may be affected too.

      Proposed fix (options)

      1. Shorten the X section. Move _dropAllTempCollections and the session scan out from under the RSTL X; they do not need the node to be write-blocked. Avoid waiting for the journal flush under X.
      2. Let the step-up give way. If the term changes while signalDrainComplete holds X, abandon the step-up and release the RSTL instead of finishing it.

            Assignee: