Disable OplogFetcher sync source re-evaluation during initial sync

XMLWordPrintableJSON

    • Type: Bug
    • Resolution: Done
    • Priority: Major - P3
    • 3.4.2, 3.5.2
    • Affects Version/s: None
    • Component/s: Replication
    • None
    • Fully Compatible
    • ALL
    • Repl 2017-01-23
    • 0
    • None
    • 3
    • None
    • None
    • None
    • None
    • None
    • None

      The OplogFetcher will terminate with an error if it decides that another sync source would be better than its current one. This causes initial sync to fail. Since initial sync does not allow for sync source changes, it should not check if there are better sync sources. If there is a problem on the sync source, it will manifest itself in the cloning phase as well, and cause a failure there.