Type:
Bug
-
Resolution: Done
-
Priority:
Major - P3
-
None
-
Affects Version/s: None
-
Component/s: WiredTiger
-
None
-
ALL
-
None
-
3
-
None
-
None
-
None
-
None
-
None
-
None
On replicaSet environments we have sometimes a crash standby node with the following error :
2017-05-22T14:04:18.973+0200 F - [conn140242] Invalid access at address: 0x3cabb4904251
2017-05-22T14:04:19.286+0200 F - [conn140242] Got signal: 11 (Segmentation fault).
Exemple
Replicaset with 3 nodes, Proxmox virtual server with 2 CPU and 6Go Ram.
Version 3.2.12, engine WT
We had this error today on recette environnement at 14:04.
I enclosed in thise ticket :
- the node logfile,
- the diagnostic data
- sar file of the day where you will find the metrics system.