Profiler should do writes with ignore-prepare set to false

XMLWordPrintableJSON

    • Type: Bug
    • Resolution: Fixed
    • Priority: Major - P3
    • 4.1.11
    • Affects Version/s: None
    • Component/s: Storage
    • None
    • Fully Compatible
    • ALL
    • Storage NYC 2019-04-22, Storage NYC 2019-05-06
    • None
    • 3
    • None
    • None
    • None
    • None
    • None
    • None
    • None

      WT-4580 will make transactions with ignore_prepare=true as readonly. Read commands that have ignore_prepare=true would still perform writes to the profiler collection if profiling is enabled.

      The solution here is to set profiler to write with ignore_prepare=false.