Flow Control should disregard faulty wall clock time readings during lag calculation

    • Type: Icon: Bug Bug
    • Resolution: Fixed
    • Priority: Icon: Major - P3 Major - P3
    • 4.2.1, 4.3.1
    • Affects Version/s: None
    • Component/s: None
    • None
    • Fully Compatible
    • ALL
    • v4.2
    • Execution Team 2019-08-26

      If the lastCommitted wall clock time is greater than the last applied wall clock time on the primary due to SERVER-42906, these values should be disregarded. Flow Control should treat this situation similarly to how it addresses faulty sample readings.