Type: Bug
-
Resolution: Done
-
Priority: Major - P3
-
Affects Version/s: None
-
Component/s: Replication
-
None
-
ALL
If a member is elected primary when the sync thread is at a certain point, the sync thread will check if the member is a secondary (which it isn't, it's primary) and then make it "go live" by changing its state to secondary. See http://buildbot.mongodb.org/builders/Windows%2064-bit%202008%2B/builds/93/steps/test/logs/stdio.