replica set recovery is this an edge case with clock times?

XMLWordPrintableJSON

    • Type: Bug
    • Resolution: Done
    • Priority: Minor - P4
    • None
    • Affects Version/s: None
    • Component/s: Replication
    • None
    • ALL
    • None
    • None
    • None
    • None
    • None
    • None
    • None

      imagine server A has writes at optimes:
      120100:0 120105:0 120109:0

      server B gets:
      120100:0 120105:0

      server A crashes. server B assumes primary.

      server B has clock skew from server A. it then writes an event
      120109:0

      Then A comes back up. The question is, is this handled properly?

            Assignee:
            Kristina Chodorow (Inactive)
            Reporter:
            Dwight Merriman
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

              Created:
              Updated:
              Resolved: