Type: Bug
-
Resolution: Fixed
-
Priority: Major - P3
-
Affects Version/s: None
-
Component/s: None
-
None
-
Fully Compatible
-
ALL
-
v5.3
-
Repl 2022-02-21, Repl 2022-03-07
This was discovered in the new test (fcbis_clear_appliedThrough_after_recovery.js) I added with "Extend Backup Cursor" for FCBIS as part of SERVER-62745. From my discussion with Matthew: We get the size storer from the initial snapshot, then we disable size adjustment during oplog replay. But for oplog entries added after the initial snapshot's recovery optime, we probably DO want size adjustment. I'm surprised we haven't seen it, we might be missing test coverage for extend.
- has to be done after
-
SERVER-63908 Fix and test partial index build handling in FCBIS
- Closed
- related to
-
SERVER-89579 FCBIS can lead to incorrect fast count on destination
- Closed