The enableSharding() command gets executed on the config server through a non-interruptible operation context

XMLWordPrintableJSON

    • Type: Task
    • Resolution: Fixed
    • Priority: Major - P3
    • 6.3.0-rc0
    • Affects Version/s: None
    • Component/s: None
    • Fully Compatible
    • Sharding EMEA 2022-10-31, Sharding EMEA 2022-11-14, Sharding EMEA 2022-12-12
    • None
    • None
    • None
    • None
    • None
    • None
    • None

      As per today, the operation context supporting the execution of _configsvrCreateDatabase is not marked as interruptible (neither by the command handler nor by the ShardingCatalogManager method implementing the service). This configuration may potentially lead to issues when the CSRS primary experiences a stepdown event.