Details

    • Type: Bug
    • Status: Closed
    • Priority: Major - P3
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: WT2.8.0
    • Labels:
      None

      Description

      test/format sanitizer failed with:

      [1456030765:134957][46588:0x7f07a36db700], t, file:wt-000015.lsm, txn-recover: wt-000015.lsm read error: failed to read 512 bytes at offset 3072: WT_ERROR: non-specific WiredTiger error
      [1456030765:135127][46588:0x7f07a36db700], t, file:wt-000015.lsm, txn-recover: Operation failed during recovery: WT_ERROR: non-specific WiredTiger error
      

      It is possible this is related to WT-2395 and WT-2346.

        Attachments

          Issue Links

            Activity

              People

              • Assignee:
                sue.loverso Sue LoVerso
                Reporter:
                sue.loverso Sue LoVerso
              • Votes:
                0 Vote for this issue
                Watchers:
                1 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: