Uploaded image for project: 'WiredTiger'
  1. WiredTiger
  2. WT-643

test/format failure: illegal cell and page type combination

    XMLWordPrintable

    Details

    • Type: Task
    • Status: Closed
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: WT1.6.5
    • Labels:

      Description

      Just saw an interesting test/format failure that I'd like to chase further:

      270: table, variable-length column-store                                     
      t, file:wt.wt, session.checkpoint: illegal cell and page type combination: cell 8 on page at [write-check] is a value/ovfl,rm cell on a row-store leaf page
      t, session.checkpoint: table:wt: WT_ERROR: non-specific WiredTiger error
      t: session.compact: WT_ERROR: non-specific WiredTiger error
      ############################################
      #  RUN PARAMETERS
      ############################################
      # bitcnt not applicable to this run
      cache=40
      compression=snappy
      data_extend=0
      data_source=table
      delete_pct=7
      dictionary=1
      file_type=row-store
      hot_backups=0
      huffman_key=0
      huffman_value=0
      insert_pct=34
      internal_key_truncation=0
      internal_page_max=13
      key_gap=16
      key_max=64
      key_min=12
      leaf_page_max=12
      ops=5000
      prefix=1
      repeat_data_pct=49
      reverse=0
      rows=100
      runs=0
      split_pct=52
      threads=20
      value_max=256
      value_min=19
      # wiredtiger_config not applicable to this run
      write_pct=45
      

        Attachments

          Issue Links

            Activity

              People

              • Assignee:
                keith.bostic Keith Bostic
                Reporter:
                keith.bostic Keith Bostic
              • Votes:
                0 Vote for this issue
                Watchers:
                1 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: