Switch the update serialization function to an atomic instruction instead of acquiring/releasing a spinlock.

XMLWordPrintableJSON

    • Type: Task
    • Resolution: Done
    • WT1.6.6
    • Affects Version/s: None
    • Component/s: None
    • None
    • None
    • None

      @michaelcahill: Is it safe to not acquire the serialization mutex when looking for obsolete WT_UPDATE entries, if we switch to an atomic instruction as our update mechanism?

            Assignee:
            Keith Bostic (Inactive)
            Reporter:
            Keith Bostic (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Created:
              Updated:
              Resolved: